Buffalo Air Handling Unit

General Construction
• 2" double wall, 14 or 16 gauge outer panels, 18 or 20 gauge inner
panels (solid or perforated),
3#/ft³ density fiberglass insulation.
• Galvanized steel, aluminum or stainless steel casings and floors
• Welded structural steel channel bases.
• 10 gauge or 3/16" welded floors in painted steel, galvanized,
aluminum or stainless steel;
treadplate optional.
• IAQ triple-sloped, 12 gauge, stainless steel drain pans in cooling coil
sections for complete condensate removal.
• Access doors for inspection, service and maintenance designed to
open
opposite the unit operating pressure.
• Maximum 1% leakage rate.
Fan Section
• Fan, motor and drive are mounted on a welded heavy duty steel vibration
base with spring
isolators properly selected for the specified vibration
efficiency. Inertia bases are available for
critical applications.
• Complete fan assembly is factory run, tested and dynamically balanced
not to exceed 0.16 ips
horizontally and vertically, and 0.32 ips axially as
measured by an Entek IRD computer balance
analyzer.
• Centrifugal fans (DWDI) for maximum efficiency in return and supply
fan applications.
• Plenum fans for return air applications and supply air applications
with multiple discharges.
• Axial fans for reduced sound levels in the low octave bands.
• Direct drive available to meet critical balance criteria, and eliminate
the possibility of belt dust
and the necessity of belt maintenance.
• Full height, full width diffuser plate in blow through applications
reduces pressure drop by
50% or more when compared to conventional diffusers.
Coil Section
• Chilled water and glycol cooling coils, hot water and glycol, and
steam heating coils.
• IAQ triple-sloped, 12 gauge stainless steel drain pans in cooling
coil
sections.
• Support racks for independent coil removal available in stainless,
galvanized or painted steel.
• Intermediate drain pans, troughs and downspouts for stacked coils.
• Steam coils raised for proper condensate removal.
• Preferred manufacturer is Aerofin.
Filter Section
• Flat and angle configurations.
• Upstream and side service options.
• ASHRAE rated, Carbon and HEPA filters
Dampers
• Opposed blade for maximum control.
• Parallel blade for mixing.
Louvers
• Drainable
• Acoustic
Blenders
Sound Attenuators
• Inlet, outlet and fan mounted.
• Sized to provide good airflow, minimum pressure drop and meet noise
criteria.
• Fiberglass filled, mylar lined, or packless
• Elbow discharge type available to meet size restraints.
Electrical Controls/Components
• Option of customized control packages to interface with building
automated control systems.
• Marine or fluorescent lights, switches and receptacles.
• Single point wiring.
• Starters, disconnects, variable frequency drives.
Piping
• Customized to the specific needs of the customer.
Thermal Break Construction
Service Corridors/Vestibules
• Side and center available on outdoor units.
Painting
• Enamel
• Epoxy
• Polyurethane
Shipping Splits
• Splits are provided to accommodate shipping restrictions, site
handling limitations and building
access dimensions.
• Full perimeter angles are supplied at each split to allow easy
reassembly at the site, and to
assure unit integrity.
• Removable lifting lugs available.
Testing
• Vibration
• Leakage
• Performance
• Sound Pressure or Sound Power
Shipment
• Units are inspected and cleaned prior to being shrink wrapped.
• All units are shrink wrapped and tarped before leaving the factory.
Service
• Servicemen available for installation supervision, start-up
assistance, owner training and trouble
shooting.
Big Buffalo -
Custom Unit
 |
• Unlimited range of
capabilities, pressures and
unit configurations.
• If you can draw it, we can build it. |
• Pre-engineered modules
to save time in
design and equipment shipment.
• K-Draw program to assist in preliminary
layout. |
Model K - Standard Unit
 |
BA 2000 -
Modular Unit
 |
• Pre-engineered modules
to save time in
design and ease of layout for customer.
• Economic savings to meet budget
constraints while maintaining
good unit
integrity.
• 10 gauge galvanized formed channel base
with 16 gauge roll
formed floors. |
Top of Page |